PCR Thermal Cycler PTC Tempo
Contact
PCR Thermal Cycler PTC Tempo
Hot cover type: automatic
Airborne operating system: Linux
Heating and cooling methods: Peltier effect
Introduction:
The PTC Tempo Thermal Cycler represents the next generation of conventional PCR thermal cyclers from Bio-Rad. Engineered to maintain thermal performance that delivers accurate results, the PTC Tempo Thermal Cycler offers the flexibility to scale with your laboratory. The new design features a refreshed, intuitive user interface and flexible connectivity options for streamlining protocol management. A motorized lid enables automation, taking your PCR to the next level with modern instrument control.
The PTC Tempo Thermal Cycler is available in multiple fixed-block configurations: PTC Tempo 96 Thermal Cycler for most general PCR applications and PTC Tempo Deepwell Thermal Cycler with larger volumes up to 125 µl.
Features and Benefits
-Programmable thermal gradient – for optimization of annealing temperatures
-Large touch screen – for streamlined protocol programming and editing
-Heated lid – for use with various vessels and sealer types
-Expanded connectivity – WiFi, ethernet, and USB
-Automated lid – for integration with automation robotics
-Cloud connectivity: create and send protocols from your BR.io cloud platform
-Network storage drive access for excellent data management
Applications and Uses
-Amplification/PCR
-Cloning
-Cycle sequencing
-Gene expression studies
-Mutagenesis
Compare This Product
PCR Thermal Cycler T100™
Contact
PCR Thermal Cycler T100™
Hot cover type: automatic
Heating and cooling methods: Peltier effect
Maximum temperature rise and fall rate: 4 ° C
Introduction:
The T100 thermal cycler is a small thermal cycler offering a comprehensive set of convenient features in a small footprint. This compact thermal cycler features an intuitive touch-screen user interface to make running PCR easy. Thermal gradient technology allows you to quickly optimize your reaction in a single run. With its robust design, the T100 system is a reliable personal thermal cycler that delivers exceptional performance for years — Launch the System Tour to test drive the T100 thermal cycler now.
Features and Benefits of the T100 Thermal Cycler
-Intuitive touch screen — easy programming using a large color touch screen and intuitive interface
-Consistent results — robust design ensures effective and consistent performance run to run
-Easy optimization — this gradient thermal cycler allows fast PCR optimization using a unique thermal gradient
-Easy protocol management — protocols can be organized using personalized folders or a USB flash drive
-Small space-saving footprint — the T100 is a compact thermal cycler that fits in any laboratory
BioRad T100 Thermal Cycler Users Around the World
Life science researchers all over the world use the T100 thermal cycler in their daily routine. In this video, real-world users describe how it saves them time and helps them consistently obtain high-quality data, with high uniformity and reproducibility. The T100 thermal cycler is praised for being user-friendly, reliable, and enjoyable to use via the touch-screen interface.
Applications and Uses for the T100 Thermal Cycler
-Nucleic acid amplification (PCR)
-Gene cloning and analysis
-Gene expression analysis
-Mutational analysis
-Cycle sequencing
Compare This Product
PCR Thermal Cycler
Contact
PCR Thermal Cycler
Hot cover type: automatic
Airborne operating system: Linux
Heating and cooling methods: Peltier effect
Introduction:
The C1000 Touch thermal cycler offers superior performance and a large color touch screen for easy programming. This fully modular platform is able to accommodate different throughput needs with easily interchangeable reaction modules that swap in seconds without tools. Each PCR module has a fully adjustable heated lid that supports a wide range of vessels and sealers, including low-profile and standard-height PCR plates.
Features and Benefits
-Quick and easy protocol programming — 2 programming options, including the Protocol Autowriter, which automatically generates customized standard, fast, and ultrafast protocols
-Easy protocol editing — the large color touch screen and redesigned navigation make editing and running protocols easy
-Flexible platform — increase throughput capability by linking up to 3 additional S1000 thermal cyclers or adding PC control for up to 32 cyclers
-Convenient file management — keep protocols organized using personalized folders or a USB flash drive
-Thermal gradient — quickly and easily identify optimal annealing temperatures by using the programmable temperature gradient
Applications and Uses
-Amplification/PCR
-Cloning
-Cycle sequencing
-Gene expression studies
-Mutagenesis
The C1000 Touch thermal cycler can be used with six interchangeable reaction modules, including:
-A gradient-enabled 96-well fast module
-A gradient-enabled 96–deep well module
-A gradient-enabled dual 48/48-well fast module that allows 2 independently controlled protocols to be run side by side in a single bay
-A gradient-enabled 384-well module for high throughput
-2 modules for real-time PCR detection
Compare This Product
PCR 热循环仪 S1000
Contact
PCR 热循环仪 S1000
Hot cover type: automatic
Heating and cooling methods: Peltier effect
Hot cover temperature range: 30-100 ° C
Introduction:
PCR Thermal Cycler
The S1000 thermal cycler combines powerful performance with streamlined features. The cycler can be used as a stand-alone instrument for PCR, or it can be connected to a C1000 Touch™ thermal cycler for additional throughput. Up to three S1000 cyclers can be connected to a C1000 Touch cycler, and the four cyclers can then be conveniently controlled as one high-throughput instrument.
Features and Benefits
-Flexible platform — choice of 4 interchangeable reaction modules; change throughput capability by linking up to 3 S1000 cyclers to a C1000 Touch cycler or adding PC control for up to 32 cyclers
-Exceptional thermal performance — the patented* reduced-mass honeycomb sample block delivers fast ramping and settling times for reliable results and reduced run times
-Optimal sealing — the fully adjustable heated lid accommodates a wide range of reaction vessels
-Thermal gradient — quickly and easily identify optimal annealing temperatures by using the programmable temperature gradient
Applications and Uses
-Amplification/PCR
-Cloning
-Cycle sequencing
-Gene expression studies
-Mutagenesis
The S1000 cycler can be used with four interchangeable reaction modules, including:
-A gradient-enabled 96-well fast module
-A gradient-enabled 96–deep well module
-A gradient-enabled dual 48/48-well fast module that allows 2 independently controlled protocols to be run side by side in a single bay
-A gradient-enabled 384-well module